Information About Single Incision Laparoscopic Surgery

By Margaret Bailey


Approaches to surgical operation are changing and evolving mostly because of major technological advancements that are being made in various fields including surgical medicine. Single incision laparoscopic surgery is often referred to using the abbreviation SILS, but it also has many other names. Among the names SILS goes by are Single-port laparoscopy, single-port access surgery (SPA), Single-access endoscopic surgery (SAES), and single-port incisionnless conventional equipment-using surgery (SPICES). Other names include natural-orifice trannsumbilical surgery (NOTUS), one-port umbilical surgery (OPUS), and laparo-endoscopic singular-site surgery (LESS).

SILS as a technique in laparoscopic surgery is still relatively new because it was only developed recently. Because this method utilizes a single entry point into the body, it is referred to as minimally invasive. The navel is the major entry point used on most patients. Only a small scar remains after the process has been done, which is one of the reasons why this process is preferred by many people.

The entry point can be made into a 20 mm or 11mm incision. The importance of utilizing only a single entry point is to minimize pain and scarring. This is opposed to traditional laparoscopic surgical procedure in which multiple entry point are made and used. New York is home to some of the most well-trained and qualified specialists in this kind of procedure. Thus it would be a great place to consider visiting if one needs such a process done to them.

The process makes use of specialized surgical equipment that can be classified into two major classes, that is hand and access ports instruments. There is a wide variety of access ports instruments including the GelPOINT system, SILS device, TriPort+, QuadPort+, TriPort15, and Uni-X. All these instruments are manufactured by different manufacturers.

Conversely, three major configurations of hand instruments exist today. They are pre-bent rigid, standard, and articulating configurations. The development of standard hand tools has been happening for more than the previous 30 years. Rigid design is used in making them. SPL reduced triangulation instrument challenge has been solved through the invetion of articulation hand instruments.

Surgeons usually have to choose whether to utilize articulating or standard instruments and that decision is often influenced by a few factors. Some of the factors include, access port used, surgical skills of the surgeon, and cost. In terms of cost, articulating instruments are considerably more expensive than standard instruments. The use of specialized devices makes this surgical procedure more effective and safer.

There is a high level of awareness of SILS among surgical doctors currently. However, it cannot be performed by any surgeon. The process is very complicated since it involves using specialized instruments through limited access space. Thus, surgical doctors who perform this process are often highly skilled and trained in surgical operation. That has made the use of this process limited and negative perceptions have followed from the public too.

A wide variety of surgeries makes use of SILS. Common examples comprise of sleeve gastrectomy, colectomy, adjustable gastric banding, appendectomy, nephrectomy, sacrocolpopexy, and hysterectomy among others. In European nations and the US, standard instruments are in wide usage when compared to specialized ones used in many other countries out of these two regions.




About the Author:



No comments :

Post a Comment